Ordering Information

For an order or quotation for a CL Leak, please provide the Part Number and confirm the Outlet Fitting for connection to your system or part. It is also necessary to specify the Gas and specific Leak Rate with your preferred leak-rate units. In addition, the Manufacturing Variance ("Tolerance") that you can allow on that Leak Rate should be specified as +/- 40% (the normal allowance), or as +/- 15% (the "Special-Range Variance"), for which there is an additional cost and an "-SR" added to the part number. An example specification is 2.0x10-5 atm-cc/sec +/- 40%. In all cases, the leak rate provided will be as close as we can make it to your specified rate, and the actual rate, as calibrated, will be recorded on the Calibration Tag and the Certifications.

Example Fittings Available

Please contact us for other fitting requirements.

Code:Description:
118T1-1/8" OD Port Tube
4FVCR¼" Female VCR
4MVCR¼" Male VCR
MCFF1.33" OD Mini Conflat Flange
2CFF2.75" OD Conflat Flange
½T½" OD Tube
KF16¾" OD ISO Flange
KF251" OD ISO Flange
KF401.5" OD ISO Flange
118T/34T1-1/8" OD Tube with step to ¾" Tube
4MPT¼" Male Normal Pipe Thread

Example Gases Available

Helium (HE), Argon (AR), Nitrogen (N2), Hydrogen (H2), Carbon Dioxide (CO2), Oxygen (O2), Air (AIR), Methane (CH4), Sulphur Hexafluoride (SF6), Refrigerants ("R"#), Xenon (XE), Deuterium (D2), Mixed gases (MIX).

Part Number Build-Up

The CL Series Part Numbers are constructed as follows:

         CL-X-BB-YYYY-ZZZZ-FVO

where X = the code for the Leak Rate Range required,

where BB = Gas to be used,

where YYYY = the fitting required*,

where ZZZZ = the Reservoir required,

and FVO = the Fill Valve Option.

A fill valve is required for many gases other than Helium, Argon, Nitrogen, Carbon Dioxide, and Air. Due to the high gas depletion rates for leak rates of 10-4 and 10-3 atm-cc/sec, these leaks must also have a fill valve for all gases. Additionally, leaks in the 10-3 range, and often in the 10-4 range, have an integral pressure gauge installed to monitor the residual pressure and indicate when filling is necessary.

* Except for Helium leaks, the fitting for 10-7 atm-cc/sec and smaller leaks must be a VCR or Conflat flange. If you require a different fitting, an adapter can be purchased.

Leak Rates Ranges Available and Example Part Numbers

Leak Rate Ranges Available for the CL Leak Range Code (X) Gas Code (BB) Fitting Code (YYYY) Res' Size Res' Code (ZZZZ) Fill Valve Example Part Number
1.0 to 9.9x10-3 atm-cc/sec
 
1.0 to 9.9x10-4 atm-cc/sec
1.0 to 9.9x10-5 atm-cc/sec
1.0 to 9.9x10-6 atm-cc/sec
1.0 to 9.9x10-7 atm-cc/sec
3 
 
4 
5 
6 
7 
AR 
 
N2 
HE 
H2 
XE 
2CFF 
 
KF25 
4MVCR 
MCFF 
2CFF 
1000 
 
1000 
500 
300 
215 
1000DOT 
 
1000DOT 
500DOT 
300DOT 
215CC 
Yes 
 
Yes 
No 
Yes 
Yes 
CL-3-AR-2CFF-1000DOT-
         MFV-1500PSI 
CL-4-N2-KF25-1000DOT-MFV 
CL-5-HE-4MVCR-500DOT 
CL-6-H2-MCFF-300DOT-MFV 
CL-7-XE-2CFF-215CC-MFV 

Note: Larger and smaller flow rates are possible. However, with leaks smaller than 10-6 atm-cc/sec there is increased risk of plugging of the capillary and precaution in use should be taken. For all leak rates, the leak's shut-off valve should be kept in the closed position when the leak is not in active use.

A fill valve is required for H2, CO, CH4, SO2, NE, KR, D2, XE and HE3. Mixed gas leaks may also need additional calibration points.