Ordering Information

For an order or quotation for a CLO Leak, please provide the Part Number, confirm the Inlet Fitting for connection to your gas source line, and confirm the Outlet Fitting for connection to the test system or part. It is also necessary to specify the Gas, the Inlet Pressure from your gas line, and the Outlet Pressure (usually vacuum or 1 atmosphere), all as used in your test and to be used for the calibration. Any dimensional requirements should also be noted.

In addition, for CLO's to be used at one Leak Rate, please state the specific Leak Rate requested (at the specified Inlet and Outlet Pressure) and your preferred leak-rate units. Also, the Manufacturing Variance ("Tolerance") that you can allow on that Leak Rate should be specified as +/- 40% (the normal allowance), or as +/- 15% (the "Special-Range Variance"), for which there is an additional cost and an "-SR" added to the part number. An example specification is 2.0x10-5 atm-cc/sec +/- 40%. In all cases, the leak rate provided will be as close as we can make it to your specified rate, and the actual rate, as calibrated, will be recorded on the Calibration Tag and the Certifications.

CLO Leaks can also be calibrated at multiple pressures to provide a range of adjustable leak rates, for example covering values from 1 to 9x10-5 atm-cc/sec using three pressures from 15 to 200 psig. VTI provides a curve of Leak Rate vs. Pressure based on the calibrations. This allows the leak rate to be changed by changing the inlet pressure and allows exact leak rates to be selected without the limitation of the manufacturing variance. For these adjustable-rate CLO's, the Leak Rate Range requested and your available Inlet Pressure Range, as well as your Outlet Pressure, should also be specified. VTI can advise on the leak-rate range achievable based on your available pressure range.

Example Fittings Available

Please contact us for other fitting requirements.

Code:Description:
118T1-1/8" OD Port Tube
4FVCR¼" Female VCR
4MVCR¼" Male VCR
MCFF1.33" OD Mini Conflat Flange
2CFF2.75" OD Conflat Flange
½T½" OD Tube
KF16¾" OD ISO Flange
KF251" OD ISO Flange
KF401.5" OD ISO Flange
118T/34T1-1/8" OD Tube with step to ¾" Tube
4MPT¼" Male Normal Pipe Thread

Part Number Build-Up

The CLO Series Part Numbers are constructed as follows:

         CLO-X-NA-BB-YYYY-ZZZZ

where X = the code for the Leak Rate Range,

where N = number of calibration points,

where A = cal method - (C for He P for other gases),

where BB = Gas to be used,

where YYYY = the INLET fitting required,

where ZZZZ = the OUTLET fitting required.

Example Gases Available

Helium (HE), Argon (AR), Nitrogen (N2), Hydrogen (H2), Carbon Dioxide (CO2), Oxygen (O2), Air (AIR), Methane (CH4), Sulphur Hexafluoride (SF6), Refrigerants ("R"#), Xenon (XE), Deuterium (D2), Mixed gases (MIX).

Leak Rates Ranges Available and Example Part Numbers

Leak Rate Ranges Available for the CLO
(Specify a value in the range for 1 cal' point or range to be covered by 3 cal' points)
Leak Range Code (X) Cal Pts & Type Code (NA) Gas Code (BB) Inlet Fitting Code (YYYY) Outlet Fitting Code (ZZZZ) Example Part Number
1.0 to 9.9x10-1 atm-cc/sec
1.0 to 3.0x10-2 atm-cc/sec
1.0 to 9.9x10-3 atm-cc/sec
1.0 to 9.9x10-4 atm-cc/sec
1.0 to 9.9x10-5 atm-cc/sec
5x10-5 to 5x10-6 atm-cc/sec
1.0 to 9.9x10-6 atm-cc/sec
1 
2 
3 
4 
5 
5/6 
6 
1C 
1P 
3P 
1P 
1P 
3P 
3C 
HE 
AR 
SF6 
AIR 
XE 
H2 
HE 
4FVCR 
4MVCR 
KF25 
4FVCR 
MCFF 
1/4T 
4MPT 
4MVCR 
MCFF 
KF40 
4MVCR 
2CFF 
2CFF 
4MPT 
CLO-1-1C-HE-4FVCR-4MCR 
CLO-2-1P-AR-4MVCR-MCFF 
CLO-3-3P-SF6-KF25-KF40 
CLO-4-1P-AIR-4FVCR-4MVCR 
CLO-5-1P-XE-MCFF-2CFF 
CLO-5/6-3P-H2-1/4T-2CFF 
CLO-6-3C-HE-4MPT-4MPT